Seitenansicht 0
Multipoint
1
1
Installation and User Instructions
PowerPack
Please read and understand these instructions before starting work.
Please leave this leaet with the user following installation
WARNING
This PowerPack must only be installed by qualied persons.
36006036 Issue 4.
®
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - Multipoint

Multipoint 1 1Installation and User InstructionsPowerPackPlease read and understand these instructions before starting work. Please leave thi

Seite 2

105.0 COMMISSIONING5.1 Once installed, the heater will operate automatically when the outlet valve is opened. The valve must be opened fully to ob

Seite 3

Multipoint 11 116.0 MULTIPLE INSTALLATIONS6.1 When larger volumes of water are required than can be provided by one heater, multiple insta

Seite 4

127.0 FAULT FINDINGYOUR SANTON POWERPACK SHOULD GIVE TROUBLE FREE OPERATION. HOWEVER SHOULD A FAULT OCCUR THE TABLE BELOW SHOULD ALLOW MOST FAULTS TO

Seite 5

Multipoint 13 13The following comprehensive list of spare parts is available for your Santon PowerPack. Please refer to the rating l

Seite 6

14This product is guaranteed against faulty materials and manufacture for a period of two years from the date of purchase provided that:1 The unit h

Seite 7

Multipoint 15 15Notes:__________________________________________________________

Seite 8 - Figure 4

16Hurricane Way, Norwich,Norfolk, NR6 6EA. www.santon.co.ukElectric Water Heating Co. 2 Horsecroft Place, PinnaclesHarlow, Essex, CM19 5

Seite 9

2Thank you for purchasing a Santon PowerPack. The PowerPack unvented pressure system water heater is manufactured to the highest standards and has bee

Seite 10

Multipoint 3 3RATED PRESSURE7kWMinimum supply pressure 0.1Mpa (1bar)Maximum supply pressure 0.25Mpa (2.5bar)9/12kWMinimum supply pressure 0.1

Seite 11

4 IMPORTANT INFORMATION2.1 Products manufactured by Santon are to British and European Standards. These appliances are safe and without risk, p

Seite 12 - 7.0 FAULT FINDING

Multipoint 5 52.5 DO NOT operate the appliance if: (in all cases turn off mains power and isolate water supply) 1. Water ceases to ow d

Seite 13

6 WATER REQUIREMENTS3.1 All 7kW heaters must be installed using the supplied 2.5bar pressure reducing valve and have a cold supply minmum pres

Seite 14 - Environmental Information

Multipoint 7 7 ELECTRICAL REQUIREMENTS3.6 This appliance must be earthed.3.7 The installation, supply cable and circuit protection must

Seite 15

8Make cut-outusing sharp knifeFigure 5 - Rear cable entryFigure 4PowerPack unit (use rear entry when it is possible)80A or 100A main switchMeterMeter

Seite 16 - Spares Stockists

Multipoint 9 9PREPARATION4.1 Remove the xing screw which holds the front cover onto the back plate of the PowerPack heater. Carefully re